Mikrotik

Mikrotik Cloudrouter Switch CRS326-24G-2S Price in Kenya

In stock
KES 35,000.00 KES 37,000.00

You save KES 2,000.00

Buy MikroTik CRS326-24G-2S+RM in Kenya at Reisen SEO. Get 24 Gigabit ports, two 10G SFP+ slots, VLAN management, and RouterOS or SwOS.

View product details
Category
Mikrotik
Availability
5 available
Need help choosing?

Talk to our team at +254 714 804 532

Product details

MikroTik CRS326-24G-2S+RM 24-Port Gigabit Switch Price in Kenya

Connect a busy wired office with 24 Gigabit Ethernet ports and 2 10G SFP+ uplink cages. The CRS326-24G-2S+RM fits sites that need managed copper access with faster backbone options. It offers RouterOS and SwOS, so the operating system can match the administrator’s switching plan.

This is the rackmount RM version, not the desktop IN enclosure and not the SwOS-only CSS326. It has no PoE output. Phones, cameras, and access points that need cable power require separate matched injectors or a PoE switch. Passive cooling suits locations where avoiding fan noise matters, but the surrounding cabinet still needs airflow. Its DC jack and passive PoE input accept 10–30V; that input feature does not supply power to clients.

Looking to purchase CRS326-24G-2S+RM in Kenya? Confirm the current stock, exact package, and total quotation with Reisen. Choose the product for the real installation rather than the model name alone.

Title: 102-mikrotik-cloudrouter-switch-crs326-24g-2srm-how-to-buy - Description: 4 buying steps for CRS326-24G-2S+RM: choose the exact item, check the package, approve a quotation, and arrange delivery.

Choose the exact model, confirm the complete package, approve the quote, and arrange delivery.

Key Specifications

Item

Details

Copper ports

24 × 10/100/1000Mbps RJ45

Fiber cages

2 × 10G SFP+

Operating systems

RouterOS and SwOS

Memory

512MB RAM; 16MB flash

Cooling

Passive

Power input

10–30V DC jack or passive PoE input

PoE output

None

Enclosure

443 × 144 × 44mm rackmount

Compatibility

Title: 102-mikrotik-cloudrouter-switch-crs326-24g-2srm-compatibility - Description: Compatibility checks for CRS326-24G-2S+RM: Interfaces: 24 × 10/100/1000Mbps RJ45; Optical links: Supported modules, matched fiber and peer; Management: Choose RouterOS or SwOS; protect access; Power: Use only this model’s specified input and output; Installation: Check rack, ventilation and cable clearance.

Use the exact supplied hardware or component specification for the final compatibility decision.

Compatibility depends on the complete connection, power, physical, and service design. Check the exact model at both ends before ordering.

Title: 102-mikrotik-cloudrouter-switch-crs326-24g-2srm-comparison-chart - Description: Physical Port Counts for CRS326-24G-2S+RM: Gigabit RJ45 24 ports, 10G SFP+ cages 2 ports. Port counts describe interfaces, not usable routed throughput.

Port counts describe interfaces, not usable routed throughput.

An office access-switch example

Plan 24 copper connections around the actual desks and uplinks. If an SFP+ cage carries the router or backbone connection, copper ports can remain available for suitable local equipment. If the uplink instead uses RJ45, include it in the copper count. A ceiling AP connected to this switch still needs a supported injector or other approved power source because this model has no PoE output. The 2 SFP+ cages can help join a faster backbone, but their existence does not make ordinary 1G clients run at 10G. A port map should show user VLANs, the management path, the upstream trunk, and any reserved ports before installation starts.

Give the backbone a clear job

A managed switch joins local network connections and gives the administrator control over how they share the network. Start by listing the devices that need a physical port. Include the router, servers, storage, access switches, and any service connection. The useful port count depends on the design. A port used for the router cannot also hold an ordinary separate client cable. Reserve space for realistic growth rather than filling every connection on installation day.

Think about where traffic moves. A backup between a server and storage device may stay inside the LAN. A cloud upload crosses the internet gateway. These jobs can have different limits even when they pass through the same switch. Draw the busy paths before deciding which connections need the fastest interfaces. This helps you spend on the links that matter instead of buying speed where it cannot be used.

Compare the physical switching role first with CRS326 Gigabit access switch and CRS317 optical aggregation switch. Check copper and optical port counts, software, and power output before treating the models as equivalents.

Match copper and optical interfaces

An RJ45 socket and an SFP+ cage solve different connection needs. Copper Ethernet uses a suitable twisted-pair lead. An SFP+ cage needs a supported optical module or another approved connection accessory. A compatible DAC can be useful for short equipment-room links. Fiber suits routes where the optical design calls for it. Neither accessory should be selected by shape alone.

For an optical link, match the speed, fiber type, connector, wavelength, distance budget, and far-end equipment. Single-strand BiDi optics need complementary transmit and receive wavelengths. Duplex optics need correct polarity. Do not force a connector into place or stare into an optical port. Keep protective caps on unused clean ports. Modules and cables contribute to the installed cost, so include them in the order plan from the start.

Choose RouterOS or SwOS deliberately

On these dual-boot CRS models, RouterOS and SwOS are alternative operating systems. They do not run side by side. SwOS focuses on switching through a browser interface. RouterOS gives a wider configuration environment, including WinBox and WebFig. Pick the operating system that suits the network and the person who will maintain it. Changing the boot choice is an administrative job that needs a planned service window.

RouterOS on a switch does not mean every routed or filtered workload runs at the sum of its port speeds. Hardware switching and CPU processing are different paths. Use supported hardware-offloaded switching for the intended Layer 2 design. Check the current device documentation before relying on a specific offload feature. A dedicated router can remain the better place for a complex internet gateway or demanding firewall policy.

For another optical port count, review CRS309 compact optical switch and CRS305 smaller SFP+ switch. Match link interfaces and installed module cost to the actual server or uplink plan.

Separate users with a documented VLAN plan

VLANs can separate staff, guest, camera, and management traffic over shared switching equipment. The benefit comes from a complete design, not merely entering VLAN numbers. Decide which ports carry ordinary untagged clients and which carry tagged traffic. Record the PVID and allowed VLANs for each role. The router or firewall must enforce the rules between those networks where required.

A wrong uplink setting can stop several rooms at once. A wrong management setting can lock the administrator out while the switch still forwards other traffic. Keep a known management path during changes. In RouterOS, use a suitable rollback method and staged configuration. Add the required bridge VLAN entries before enabling filtering. Test the upstream trunk and an ordinary client before moving the whole site across.

A different management ecosystem is available through UniFi 16 XG alternative and UniFi Standard 24 alternative. These options need their own software and support plan, so compare ownership needs as well as ports.

Keep loops and shared uplinks under control

Extra inter-switch cables do not automatically add useful bandwidth. Without a supported aggregation or loop-control design, they can create a broadcast storm. Use RSTP and the correct port roles where the design needs loop protection. Configure link aggregation at both endpoints only when both support the selected method. Two independent cables are not a working aggregate just because they join the same devices.

The uplink is shared by traffic that crosses it. A fast server port cannot make a slower uplink disappear. Compare port counters during a real busy period and check whether local traffic or internet traffic is the concern. A single speed-test result cannot fully describe switch performance. Use repeatable local tests with capable endpoints and keep the test conditions in the service record.

Treat power as a separate specification

PoE input, PoE output, passive PoE, and 802.3af/at are different features. Use only the power functions listed for the exact model. A switch with no PoE output cannot power a camera through its data ports. A passive powered connection must match voltage and wiring. Where the switch supports standards-based detection, leave protection in place rather than forcing power onto an unknown load.

For a PoE model, add maximum endpoint demand and check shared limits as well as per-port limits. Some devices draw more during startup or when infrared lighting turns on. Cable loss also matters. Allocate spare capacity for a realistic expansion. Keep data-only equipment away from any forced passive output arrangement. A careful power schedule helps prevent restarts that can otherwise look like a network fault.

For equipment-room connections, examine CRS312 copper 10G alternative and 1m 10G DAC accessory. A DAC must be supported at both ends; its listing alone is not proof of compatibility with every cage.

Install for cooling and service access

Use a dry indoor location with space for the specified chassis, plugs, and cable bends. Rack height alone does not establish usable depth. The mount must support the actual device, and ventilation openings must stay clear. Secure the power leads and patch cables so they do not hang from sockets. Keep fiber bends gentle and use proper cable guides.

Check temperature and port errors after the site carries normal traffic. A cabinet that looks tidy can still trap warm air. Fan behavior can change as the enclosure warms up, and optical modules add heat. Do not treat a quiet startup as a permanent cooling result. Keep the device model, serial number, software version, management address, and configuration backup in the owner’s records.

Plan cable length and the access layer using 3m 10G DAC accessory and managed-switch choices. Check the full forwarding design rather than buying a second uplink without loop or aggregation controls.

Quick Brand Comparison

Family

Main buying distinction

MikroTik RouterOS or CRS

Model-specific routing, switching, and power

TP-Link unmanaged or consumer

Exact speed, role, and revision

UniFi managed equipment

Controller ecosystem and supported interfaces

Other comparable equipment

Complete installed cost, compatibility, and service support

 

Compare exact models and complete installation requirements. A brand family is a starting point, not evidence that every product has the same ports, power, software, or optical behavior.

Can It Be Used with Starlink?

Yes, it can serve in a suitable downstream Ethernet network fed by Starlink. Connect from the supported Starlink Ethernet handoff through the planned gateway or LAN design. Use matching uplinks and keep DHCP responsibilities clear. It does not power the dish or increase the subscribed internet rate.

For terminal-side and site-connectivity planning, review Starlink Kenya Installers and SpaceLink Internet Kenya. Match the local network to the exact terminal generation and approved handoff. Local hardware capability and satellite service performance are separate limits.

How to Set Up CRS326-24G-2S+RM

A Step by Step Guide

1. Plan the ports and management path

List uplinks, client ports, optical accessories, VLANs, and power needs. Set aside a trusted connection for setup. Compare the labels on the delivered switch and modules with the approved parts list. Work locally before placing the switch into the live network so an incorrect default or address does not disrupt existing users.

2. Mount and power the correct model

Fit the supported rack hardware or other approved mounting arrangement. Leave room for ventilation, module removal, and cable bends. Use the specified power input. Where there are 2 supplies, connect them to the planned circuits. Check the power and fault indicators before attaching production links.

3. Connect a local setup computer

Use a known-good copper lead or another supported management connection. Read the supplied quick guide and device label for initial access. If IP access is unavailable, RouterOS may allow local MAC WinBox discovery from a permitted interface. SwOS uses its browser interface. Do not expose initial setup to the public internet.

4. Secure the administrator account

Set a unique password and record the chosen operating system. Use a conflict-free management address in the intended subnet. Restrict administration to trusted hosts or management networks. Update only with software for the exact model and a supported release path. Save a baseline configuration before making larger changes.

5. Build the bridge and VLAN design

In RouterOS, inspect existing settings first, then configure the intended bridge, ports, and supported hardware offload. Add tagged and untagged membership and PVIDs from the written plan. Preserve management access before enabling VLAN filtering. In SwOS, use the matching version’s VLAN controls rather than pasting RouterOS commands.

6. Check optics and any endpoint power

Install supported modules with clean matching patch leads. Confirm the far-end link rate and optical status where exposed. For a PoE switch, verify detection mode, endpoint voltage, individual demand, and shared budgets before enabling loads. A data-only model needs separate approved power for cameras and access points.

7. Test each network and important service

Connect one sample client for every port role. Check addressing, DNS, gateway access, and approved internet use. Confirm that isolated networks cannot cross the firewall policy. Run a local transfer on the faster paths and watch errors and load. If a test fails, change one cause at a time.

8. Save and hand over the working design

Save persistent settings using the operating system’s supported method. Keep a backup, port map, module list, and test record. Label cables at both ends. Check access after a planned restart and verify any recovery connection. Give the owner secure access records without printing passwords on public equipment labels.

Advantages

·       Managed control for a planned local network.

·       Useful copper or optical port layout for the specified role.

·       RouterOS or SwOS choice on these exact CRS models.

Disadvantages and Limits

·       Optics and supporting connection parts can add to the installed cost.

·       VLAN and management changes need a deliberate plan.

·       Use only the exact model’s supported power and forwarding functions.

Frequently Asked Questions

Is this an internet router replacement?

Its main role is switching. Some RouterOS routing features are available, but the right gateway depends on the required throughput and rules. Keep router and switch performance separate when planning the network.

Do I need WinBox for every setup?

WinBox is a RouterOS management application. WebFig is the browser interface for RouterOS. SwOS has its own browser interface. Use the method for the operating system actually running on the device.

Are SFP+ modules included?

Do not assume they are. Select supported modules or DAC cables for both endpoints and include them in the quotation. Connector type, fiber, distance, and optical budget must match.

Will a faster switch increase my subscription speed?

It can remove a local bottleneck when the rest of the path supports it. It does not change the internet package, provider congestion, server response, or a slower client interface.

Can I connect more than one uplink?

Only with a supported planned topology. Uncontrolled parallel links can create loops. Configure aggregation or a loop-protection design correctly at both ends and verify the actual forwarding behavior.

Can it power all of my devices?

Only a model with suitable PoE output can power supported endpoints, within its electrical limits. Check the specification table and each device’s demand. Data ports alone do not prove any power capability.

Complete the Installation with Reisen

Build a clear parts list around MikroTik hEX RB750Gr3 5-Port Gigabit Router and MikroTik CCR2004-1G-12S+2XS Cloud Core Router. Choose each item for a defined role and confirm the links, power, and supplied accessories before combining them.

For another part of the installation, review Easenet Cat6 Indoor Ethernet Cable and MikroTik cAP ac RBcAPGi-5acD2nD Wireless Access Point. A shared brand does not prove compatibility. Read the actual interface and power requirements on both sides.

Keep the service and connection roles distinct when selecting Netlink Single-mode Media Converter and Netlink Gigabit Single-mode Media Converter. These are complementary tools or network choices, not a promise that every item plugs directly into every other item.

The next stage of the project may need Fiber SC/UPC Fast Connector and Fiber Optic SC/APC Fast Connector. Ask for a quotation that marks each item as required, optional, or an alternative, so the complete package stays easy to review.

For the wider network, examine MikroTik PowerBox Pro RB960PGS-PB Outdoor Router and TP-Link TL-SF1024D 24-Port Fast Ethernet Switch. Keep the main device, cable routes, and distribution equipment aligned with the planned service. Check each exact model before adding it to the order.

Choosing the right package in Kenya

If you are asking where to buy CRS326-24G-2S+RM in Kenya, start with the exact model and the job it needs to do. Send Reisen the quantity, delivery location, and intended installation date. Include the equipment already in use and any important service requirement. A clear request helps distinguish a direct replacement from a new design that needs extra parts.

The cost of CRS326-24G-2S+RM should be reviewed as part of the complete working package. Ask whether the quoted amount includes taxes, the required accessories, delivery, and any agreed technical work. Hardware, setup labor, and an ongoing provider subscription are different charges. Keep them itemized. This makes the order easier to approve and avoids comparing a bare unit with a fully prepared installation.

What’s in the Box

Manufacturer package contents.

·       CRS326-24G-2S+RM switch

·       24V 1.2A power adapter

·       Rackmount ears

·       Screw set

Confirm the local mains plug. SFP+ modules and connection cables are not assumed included.

Check the sealed package and item list when it arrives. Keep the invoice and model or batch information. Photograph visible shipping damage before discarding the packing materials, and contact Reisen promptly if an item is missing or differs from the order. A package seen in a video may be from another region or revision, so use the actual quotation as the reference for your delivery.

Warranty

Ask Reisen to confirm the current warranty period, coverage, exclusions, and claim process for CRS326-24G-2S+RM in writing before payment. This description does not set a new warranty duration. Confirm who handles assessment, whether a local service route is available, and which supporting records are required. Keep the invoice and any serial or batch details with the product records.

If a fault appears, record the symptoms and any safe checks already performed. Do not open sealed equipment, modify power connections, or attempt an unauthorized repair while seeking a warranty decision. For installation-related concerns, keep the wiring, power, handling, and test records available. They can help separate a product fault from a problem elsewhere in the system without assuming the outcome of a claim.

Return Policy

Confirm Reisen’s current return window, eligibility rules, assessment process, and delivery-charge responsibilities before ordering. Ask specifically about opened, cut, assembled, registered, configured, or specially sourced items where relevant. Do not assume that every product can be returned after installation or that a refund is automatic. The applicable written policy and the circumstances of the order determine the process.

If the wrong item arrives, keep it protected and contact the team with the order reference before using or altering it. Retain packaging and accessories while the issue is reviewed. For a compatibility concern, share the exact connected-device labels and intended use. Getting those details checked before dispatch is usually simpler than arranging a return after the installation has begun.

Product Guides and Documents

Keep the exact product identification, matching technical sheet, supplied quick guide, packing list, quotation, and test record together. For CRS326-24G-2S+RM, ask for documents that match the actual hardware or component revision. A similar product’s guide can help explain a general idea, but its power ratings, preparation dimensions, or software controls must not be copied without verification.

Where a technical value is essential to the project, have it written into the approved specification. This may include optical parameters, interface rates, supported power, physical fit, or material grade. If no exact manufacturer SKU is supplied, request that identification before accepting a fixed performance promise. Clear documentation helps with replacements, future expansion, and handing the system to another technician.

Installation Manuals

Use the installation manual for the delivered unit as the final reference for assembly, safe handling, power, mounting, and recovery. The step-by-step guide on this page explains a practical workflow, but it does not replace model-specific dimensions or safety instructions. Ask Reisen for the matching manual before an installer travels to the site, especially when a missing adapter, bracket, or tool could stop the work.

Keep the installed layout and any approved settings with the manual. Record changes after maintenance rather than leaving the original plan out of date. For a provider-controlled product, retain the operator’s instructions as well. For passive components, keep the preparation and test procedure. This gives the owner a useful record instead of relying on memory when another part needs replacement.

Why Shop with Reisen

Reisen brings network equipment, connection parts, and installation accessories into one catalog. That lets you build the order around the job rather than buy a main device and discover missing parts later. Ask the team for current stock information, a clear itemized quotation, and technical checks for the models you already own. Confirm collection, delivery, and after-sales arrangements before approving the package.

We’re working to make Reisen a Leading eCommerce platform in Kenya and a Leading eCommerce platform in Africa through useful product information and clear buying support. For your order, focus on the promises written into the quotation: exact goods, condition, price, included parts, delivery terms, and agreed support. Keep those details together so follow-up questions can be handled against a clear record.

Order CRS326-24G-2S+RM from Reisen

Ready to buy CRS326-24G-2S+RM? Open MikroTik CRS326-24G-2S+RM 24-Port Gigabit Switch and confirm the current package with Reisen. Share your quantity, location, and intended use. If installation or configuration is required, request its scope and price separately. Approve the model and accessory list before payment, then arrange collection or delivery using the confirmed order details.

After delivery, check the package before the installation date. Complete the appropriate physical, connection, and service tests at handover. Save the invoice, guides, and test results for later support. A well-chosen product is most useful when the equipment, installation method, and owner’s needs fit the same plan.

Additional information

ProductMikrotik Cloudrouter Switch CRS326-24G-2S Price in Kenya
CategoryMikrotik
PriceKES 35,000.00
AvailabilityIn stock
Keep exploringMore in Mikrotik