Select an image to view it. Click the main image to enlarge.
Mikrotik Cloudrouter Switch CRS328-24P-4S+RM Price in Kenya
You save KES 3,000.00
Buy MikroTik CRS328-24P-4S+RM in Kenya at Reisen SEO. Get 24 Gigabit PoE ports, four 10G SFP+ slots, a 450W PoE budget, and managed switching.
View product detailsTalk to our team at +254 714 804 532
Product details
MikroTik CRS328-24P-4S+RM 24-Port Gigabit PoE+ Switch Price in Kenya
Bring Ethernet data and compatible device power into the same rack. The CRS328-24P-4S+RM combines 24 Gigabit PoE-out ports with 4 10G SFP+ cages. It serves camera, phone, and access-point networks that need managed switching and a documented power plan.
The 450W PoE allowance is divided into 3 groups of 8 ports, with 150W per group. A supported port can provide up to 30W, but 24 devices cannot all draw 30W at once. Spread demanding endpoints across the power groups. Use automatic detection for supported 802.3af/at devices and check voltage requirements before using passive settings. The internal power supply is rated 500W; that is not a 500W endpoint budget. Fan noise and heat matter when choosing the rack location.
Looking to purchase CRS328-24P-4S+RM in Kenya? Confirm the current stock, exact package, and total quotation with Reisen. Choose the product for the real installation rather than the model name alone.
Choose the exact model, confirm the complete package, approve the quote, and arrange delivery.
Key Specifications
|
Item |
Details |
|
Ports |
24 × Gigabit RJ45; 4 × 10G SFP+ |
|
PoE methods |
802.3af/at and supported passive output modes |
|
Total PoE allocation |
450W across 3 × 150W groups of 8 ports |
|
Per-port PoE maximum |
Up to 30W within group and total limits |
|
Software |
RouterOS or SwOS |
|
Memory |
128MB RAM |
|
Supply |
Internal 500W AC supply |
|
Cooling |
2 fans |
|
Dimensions |
443 × 300 × 44mm |
Compatibility
Use the exact supplied hardware or component specification for the final compatibility decision.
Compatibility depends on the complete connection, power, physical, and service design. Check the exact model at both ends before ordering.
450W total; up to 30W per supported port within all limits.
A camera and access-point power example
List each endpoint’s maximum demand rather than only its normal daytime reading. A camera may draw more when infrared illumination starts, while an access point can change demand with use. Allocate devices against the 150W allowance for their group of 8 ports and the 450W total. Leave an appropriate margin instead of assigning every group exactly at its ceiling. Keep data-only clients separate from any deliberately configured passive-power use. For a cold-start test, verify that the intended set of devices can start together without exceeding the documented limits. Record which endpoint sits on each port so a later addition does not overload a group that previously looked lightly used.
Give the backbone a clear job
A managed switch joins local network connections and gives the administrator control over how they share the network. Start by listing the devices that need a physical port. Include the router, servers, storage, access switches, and any service connection. The useful port count depends on the design. A port used for the router cannot also hold an ordinary separate client cable. Reserve space for realistic growth rather than filling every connection on installation day.
Think about where traffic moves. A backup between a server and storage device may stay inside the LAN. A cloud upload crosses the internet gateway. These jobs can have different limits even when they pass through the same switch. Draw the busy paths before deciding which connections need the fastest interfaces. This helps you spend on the links that matter instead of buying speed where it cannot be used.
For additional equipment in the wider installation, review managed-switch choices. Match the actual hardware label and accessories before approving a cross-brand or cross-version replacement.
Match copper and optical interfaces
An RJ45 socket and an SFP+ cage solve different connection needs. Copper Ethernet uses a suitable twisted-pair lead. An SFP+ cage needs a supported optical module or another approved connection accessory. A compatible DAC can be useful for short equipment-room links. Fiber suits routes where the optical design calls for it. Neither accessory should be selected by shape alone.
For an optical link, match the speed, fiber type, connector, wavelength, distance budget, and far-end equipment. Single-strand BiDi optics need complementary transmit and receive wavelengths. Duplex optics need correct polarity. Do not force a connector into place or stare into an optical port. Keep protective caps on unused clean ports. Modules and cables contribute to the installed cost, so include them in the order plan from the start.
Choose RouterOS or SwOS deliberately
On these dual-boot CRS models, RouterOS and SwOS are alternative operating systems. They do not run side by side. SwOS focuses on switching through a browser interface. RouterOS gives a wider configuration environment, including WinBox and WebFig. Pick the operating system that suits the network and the person who will maintain it. Changing the boot choice is an administrative job that needs a planned service window.
RouterOS on a switch does not mean every routed or filtered workload runs at the sum of its port speeds. Hardware switching and CPU processing are different paths. Use supported hardware-offloaded switching for the intended Layer 2 design. Check the current device documentation before relying on a specific offload feature. A dedicated router can remain the better place for a complex internet gateway or demanding firewall policy.
Compare the physical switching role first with UniFi Standard 24 PoE alternative and CRS317 optical aggregation switch. Check copper and optical port counts, software, and power output before treating the models as equivalents.
Separate users with a documented VLAN plan
VLANs can separate staff, guest, camera, and management traffic over shared switching equipment. The benefit comes from a complete design, not merely entering VLAN numbers. Decide which ports carry ordinary untagged clients and which carry tagged traffic. Record the PVID and allowed VLANs for each role. The router or firewall must enforce the rules between those networks where required.
A wrong uplink setting can stop several rooms at once. A wrong management setting can lock the administrator out while the switch still forwards other traffic. Keep a known management path during changes. In RouterOS, use a suitable rollback method and staged configuration. Add the required bridge VLAN entries before enabling filtering. Test the upstream trunk and an ordinary client before moving the whole site across.
For another optical port count, review CRS326 Gigabit access switch and CRS309 compact optical switch. Match link interfaces and installed module cost to the actual server or uplink plan.
Keep loops and shared uplinks under control
Extra inter-switch cables do not automatically add useful bandwidth. Without a supported aggregation or loop-control design, they can create a broadcast storm. Use RSTP and the correct port roles where the design needs loop protection. Configure link aggregation at both endpoints only when both support the selected method. Two independent cables are not a working aggregate just because they join the same devices.
The uplink is shared by traffic that crosses it. A fast server port cannot make a slower uplink disappear. Compare port counters during a real busy period and check whether local traffic or internet traffic is the concern. A single speed-test result cannot fully describe switch performance. Use repeatable local tests with capable endpoints and keep the test conditions in the service record.
Treat power as a separate specification
PoE input, PoE output, passive PoE, and 802.3af/at are different features. Use only the power functions listed for the exact model. A switch with no PoE output cannot power a camera through its data ports. A passive powered connection must match voltage and wiring. Where the switch supports standards-based detection, leave protection in place rather than forcing power onto an unknown load.
For a PoE model, add maximum endpoint demand and check shared limits as well as per-port limits. Some devices draw more during startup or when infrared lighting turns on. Cable loss also matters. Allocate spare capacity for a realistic expansion. Keep data-only equipment away from any forced passive output arrangement. A careful power schedule helps prevent restarts that can otherwise look like a network fault.
A different management ecosystem is available through CRS305 smaller SFP+ switch and UniFi 16 XG alternative. These options need their own software and support plan, so compare ownership needs as well as ports.
Install for cooling and service access
Use a dry indoor location with space for the specified chassis, plugs, and cable bends. Rack height alone does not establish usable depth. The mount must support the actual device, and ventilation openings must stay clear. Secure the power leads and patch cables so they do not hang from sockets. Keep fiber bends gentle and use proper cable guides.
Check temperature and port errors after the site carries normal traffic. A cabinet that looks tidy can still trap warm air. Fan behavior can change as the enclosure warms up, and optical modules add heat. Do not treat a quiet startup as a permanent cooling result. Keep the device model, serial number, software version, management address, and configuration backup in the owner’s records.
For equipment-room connections, examine UniFi Standard 24 alternative and CRS312 copper 10G alternative. A DAC must be supported at both ends; its listing alone is not proof of compatibility with every cage.
Plan cable length and the access layer using 1m 10G DAC accessory and 3m 10G DAC accessory. Check the full forwarding design rather than buying a second uplink without loop or aggregation controls.
Quick Brand Comparison
|
Family |
Main buying distinction |
|
MikroTik RouterOS or CRS |
Model-specific routing, switching, and power |
|
TP-Link unmanaged or consumer |
Exact speed, role, and revision |
|
UniFi managed equipment |
Controller ecosystem and supported interfaces |
|
Other comparable equipment |
Complete installed cost, compatibility, and service support |
Compare exact models and complete installation requirements. A brand family is a starting point, not evidence that every product has the same ports, power, software, or optical behavior.
Can It Be Used with Starlink?
Yes, it can serve in a suitable downstream Ethernet network fed by Starlink. Connect from the supported Starlink Ethernet handoff through the planned gateway or LAN design. Use matching uplinks and keep DHCP responsibilities clear. It does not power the dish or increase the subscribed internet rate.
For terminal-side and site-connectivity planning, review Starlink Kenya Installers and SpaceLink Internet Kenya. Match the local network to the exact terminal generation and approved handoff. Local hardware capability and satellite service performance are separate limits.
How to Set Up CRS328-24P-4S+RM
A Step by Step Guide
1. Plan the ports and management path
List uplinks, client ports, optical accessories, VLANs, and power needs. Set aside a trusted connection for setup. Compare the labels on the delivered switch and modules with the approved parts list. Work locally before placing the switch into the live network so an incorrect default or address does not disrupt existing users.
2. Mount and power the correct model
Fit the supported rack hardware or other approved mounting arrangement. Leave room for ventilation, module removal, and cable bends. Use the specified power input. Where there are 2 supplies, connect them to the planned circuits. Check the power and fault indicators before attaching production links.
3. Connect a local setup computer
Use a known-good copper lead or another supported management connection. Read the supplied quick guide and device label for initial access. If IP access is unavailable, RouterOS may allow local MAC WinBox discovery from a permitted interface. SwOS uses its browser interface. Do not expose initial setup to the public internet.
4. Secure the administrator account
Set a unique password and record the chosen operating system. Use a conflict-free management address in the intended subnet. Restrict administration to trusted hosts or management networks. Update only with software for the exact model and a supported release path. Save a baseline configuration before making larger changes.
5. Build the bridge and VLAN design
In RouterOS, inspect existing settings first, then configure the intended bridge, ports, and supported hardware offload. Add tagged and untagged membership and PVIDs from the written plan. Preserve management access before enabling VLAN filtering. In SwOS, use the matching version’s VLAN controls rather than pasting RouterOS commands.
6. Check optics and any endpoint power
Install supported modules with clean matching patch leads. Confirm the far-end link rate and optical status where exposed. For a PoE switch, verify detection mode, endpoint voltage, individual demand, and shared budgets before enabling loads. A data-only model needs separate approved power for cameras and access points.
7. Test each network and important service
Connect one sample client for every port role. Check addressing, DNS, gateway access, and approved internet use. Confirm that isolated networks cannot cross the firewall policy. Run a local transfer on the faster paths and watch errors and load. If a test fails, change one cause at a time.
8. Save and hand over the working design
Save persistent settings using the operating system’s supported method. Keep a backup, port map, module list, and test record. Label cables at both ends. Check access after a planned restart and verify any recovery connection. Give the owner secure access records without printing passwords on public equipment labels.
Advantages
· Managed control for a planned local network.
· Useful copper or optical port layout for the specified role.
· RouterOS or SwOS choice on these exact CRS models.
Disadvantages and Limits
· Optics and supporting connection parts can add to the installed cost.
· VLAN and management changes need a deliberate plan.
· Use only the exact model’s supported power and forwarding functions.
Frequently Asked Questions
Is this an internet router replacement?
Its main role is switching. Some RouterOS routing features are available, but the right gateway depends on the required throughput and rules. Keep router and switch performance separate when planning the network.
Do I need WinBox for every setup?
WinBox is a RouterOS management application. WebFig is the browser interface for RouterOS. SwOS has its own browser interface. Use the method for the operating system actually running on the device.
Are SFP+ modules included?
Do not assume they are. Select supported modules or DAC cables for both endpoints and include them in the quotation. Connector type, fiber, distance, and optical budget must match.
Will a faster switch increase my subscription speed?
It can remove a local bottleneck when the rest of the path supports it. It does not change the internet package, provider congestion, server response, or a slower client interface.
Can I connect more than one uplink?
Only with a supported planned topology. Uncontrolled parallel links can create loops. Configure aggregation or a loop-protection design correctly at both ends and verify the actual forwarding behavior.
Can it power all of my devices?
Only a model with suitable PoE output can power supported endpoints, within its electrical limits. Check the specification table and each device’s demand. Data ports alone do not prove any power capability.
Complete the Installation with Reisen
Build a clear parts list around MikroTik hEX RB750Gr3 5-Port Gigabit Router and MikroTik CCR2004-1G-12S+2XS Cloud Core Router. Choose each item for a defined role and confirm the links, power, and supplied accessories before combining them.
For another part of the installation, review Easenet Cat6 Indoor Ethernet Cable and MikroTik cAP ac RBcAPGi-5acD2nD Wireless Access Point. A shared brand does not prove compatibility. Read the actual interface and power requirements on both sides.
Keep the service and connection roles distinct when selecting Netlink Single-mode Media Converter and Netlink Gigabit Single-mode Media Converter. These are complementary tools or network choices, not a promise that every item plugs directly into every other item.
The next stage of the project may need Fiber SC/UPC Fast Connector and Fiber Optic SC/APC Fast Connector. Ask for a quotation that marks each item as required, optional, or an alternative, so the complete package stays easy to review.
For the wider network, examine MikroTik CRS326-24G-2S+RM 24-Port Gigabit Switch and MikroTik PowerBox Pro RB960PGS-PB Outdoor Router. Keep the main device, cable routes, and distribution equipment aligned with the planned service. Check each exact model before adding it to the order.
Choosing the right package in Kenya
If you are asking where to buy CRS328-24P-4S+RM in Kenya, start with the exact model and the job it needs to do. Send Reisen the quantity, delivery location, and intended installation date. Include the equipment already in use and any important service requirement. A clear request helps distinguish a direct replacement from a new design that needs extra parts.
The cost of CRS328-24P-4S+RM should be reviewed as part of the complete working package. Ask whether the quoted amount includes taxes, the required accessories, delivery, and any agreed technical work. Hardware, setup labor, and an ongoing provider subscription are different charges. Keep them itemized. This makes the order easier to approve and avoids comparing a bare unit with a fully prepared installation.
What’s in the Box
Manufacturer package contents.
· CRS328-24P-4S+RM switch
· Rackmount ears
· IEC power cord
· K54 fastening kit
Fiber modules, copper leads, powered endpoints, and UPS equipment are separate unless listed in the order.
Check the sealed package and item list when it arrives. Keep the invoice and model or batch information. Photograph visible shipping damage before discarding the packing materials, and contact Reisen promptly if an item is missing or differs from the order. A package seen in a video may be from another region or revision, so use the actual quotation as the reference for your delivery.
Warranty
Ask Reisen to confirm the current warranty period, coverage, exclusions, and claim process for CRS328-24P-4S+RM in writing before payment. This description does not set a new warranty duration. Confirm who handles assessment, whether a local service route is available, and which supporting records are required. Keep the invoice and any serial or batch details with the product records.
If a fault appears, record the symptoms and any safe checks already performed. Do not open sealed equipment, modify power connections, or attempt an unauthorized repair while seeking a warranty decision. For installation-related concerns, keep the wiring, power, handling, and test records available. They can help separate a product fault from a problem elsewhere in the system without assuming the outcome of a claim.
Return Policy
Confirm Reisen’s current return window, eligibility rules, assessment process, and delivery-charge responsibilities before ordering. Ask specifically about opened, cut, assembled, registered, configured, or specially sourced items where relevant. Do not assume that every product can be returned after installation or that a refund is automatic. The applicable written policy and the circumstances of the order determine the process.
If the wrong item arrives, keep it protected and contact the team with the order reference before using or altering it. Retain packaging and accessories while the issue is reviewed. For a compatibility concern, share the exact connected-device labels and intended use. Getting those details checked before dispatch is usually simpler than arranging a return after the installation has begun.
Product Guides and Documents
Keep the exact product identification, matching technical sheet, supplied quick guide, packing list, quotation, and test record together. For CRS328-24P-4S+RM, ask for documents that match the actual hardware or component revision. A similar product’s guide can help explain a general idea, but its power ratings, preparation dimensions, or software controls must not be copied without verification.
Where a technical value is essential to the project, have it written into the approved specification. This may include optical parameters, interface rates, supported power, physical fit, or material grade. If no exact manufacturer SKU is supplied, request that identification before accepting a fixed performance promise. Clear documentation helps with replacements, future expansion, and handing the system to another technician.
Installation Manuals
Use the installation manual for the delivered unit as the final reference for assembly, safe handling, power, mounting, and recovery. The step-by-step guide on this page explains a practical workflow, but it does not replace model-specific dimensions or safety instructions. Ask Reisen for the matching manual before an installer travels to the site, especially when a missing adapter, bracket, or tool could stop the work.
Keep the installed layout and any approved settings with the manual. Record changes after maintenance rather than leaving the original plan out of date. For a provider-controlled product, retain the operator’s instructions as well. For passive components, keep the preparation and test procedure. This gives the owner a useful record instead of relying on memory when another part needs replacement.
Why Shop with Reisen
Reisen brings network equipment, connection parts, and installation accessories into one catalog. That lets you build the order around the job rather than buy a main device and discover missing parts later. Ask the team for current stock information, a clear itemized quotation, and technical checks for the models you already own. Confirm collection, delivery, and after-sales arrangements before approving the package.
We’re working to make Reisen a Leading eCommerce platform in Kenya and a Leading eCommerce platform in Africa through useful product information and clear buying support. For your order, focus on the promises written into the quotation: exact goods, condition, price, included parts, delivery terms, and agreed support. Keep those details together so follow-up questions can be handled against a clear record.
Order CRS328-24P-4S+RM from Reisen
Ready to buy CRS328-24P-4S+RM? Open MikroTik CRS328-24P-4S+RM 24-Port Gigabit PoE+ Switch and confirm the current package with Reisen. Share your quantity, location, and intended use. If installation or configuration is required, request its scope and price separately. Approve the model and accessory list before payment, then arrange collection or delivery using the confirmed order details.
After delivery, check the package before the installation date. Complete the appropriate physical, connection, and service tests at handover. Save the invoice, guides, and test results for later support. A well-chosen product is most useful when the equipment, installation method, and owner’s needs fit the same plan.
Additional information
| Product | Mikrotik Cloudrouter Switch CRS328-24P-4S+RM Price in Kenya |
|---|---|
| Category | Mikrotik |
| Price | KES 65,000.00 |
| Availability | In stock |